Fuel Treatment Chemicals Manufacturer in India
RUB FLOCK 500 – Soot and Fire Scale Remover for Boiler Fire-Side Treatment
RUB FLOCK 500 is a dry powder fuel treatment chemical used as a soot and fire scale remover for boiler fire-side treatment applications. It is formulated to support removal and prevention of soot and fire scale deposits in boiler fire zones, heat transfer areas, economizers, superheaters, exhaust paths, and stacks.
RUB FLOCK 500 can help support combustion efficiency, heat transfer, soot blowing, clinker reduction, and fire-side deposit control where fuel-related soot and scale formation are present. Product dosage and frequency should be confirmed based on fuel type, severity of deposits, boiler operating conditions, and technical evaluation.
Need a Soot and Fire Scale Remover?
Applications of RUB FLOCK 500
| APPLICATION AREA | USE |
|---|---|
| Boiler Fire-Side Treatment | Supports soot and fire scale removal in boiler fire zones |
| Furnaces | Helps manage soot and deposit-related issues |
| Heat Exchangers | Supports cleaner heat transfer surfaces |
| Superheaters | Helps reduce fire-side deposit build-up where suitable |
| Economizers | Supports soot and scale control in heat recovery areas |
| Exhaust Paths and Stacks | Helps manage soot-related deposits in exhaust systems |
| Solid Fuel / Coal-Fired Systems | Supports clinker and soot control where technically suitable |
| Industrial Fuel Systems | Fuel treatment support based on operating conditions |
Benefits of RUB FLOCK 500
- Easy-to-use dry powder fuel treatment chemical
- Supports removal and prevention of soot and fire scale deposits
- Helps reduce clinker formation
- Supports reduction of fouling in boiler fire-side areas
- Helps reduce unburnt carbon where suitable
- Supports soot blowing effectiveness
- Helps improve heat transfer by managing deposit build-up
- Supports combustion efficiency in suitable fuel systems
- Can help reduce particulate matter in exhaust gas, subject to operating conditions and technical evaluation
Technical Specifications of RUB FLOCK 500
| PROPERTY | VALUE |
|---|---|
| Product Name | RUB FLOCK 500 |
| Product Category | Fuel Treatment Chemical / Soot and Fire Scale Remover |
| Form | Dry Powder Compound |
| Main Applications | Boiler fire-side treatment, soot removal, fire scale removal, clinker reduction, fouling reduction, combustion support |
| Application Area | Boiler fire zones, heat exchangers, superheaters, economizers, exhaust paths, stacks |
| Dosage Basis | Based on fuel consumption and severity of deposits |
| Related Products | Boiler Water Treatment Chemicals, Cooling Water Chemicals |
Dose Rate Guidance
| FUEL CONSUMPTION | SUGGESTED DOSE PER DAY |
|---|---|
| 5 tons/day | 1.0 kg/day |
| 10 tons/day | 2.0 kg/day |
| 18 tons/day | 3.0 kg/day |
| 24 tons/day | 3.5 kg/day |
| 30 tons/day | 4.0 kg/day |
| 40 tons/day | 4.5 kg/day |
| 50 tons/day | 5.0 kg/day |
| 80 tons/day | 6.0 kg/day |
| 100 tons/day | 6.5 kg/day |
| 130 tons/day | 7.0 kg/day |
Application Method
RUB FLOCK 500 may be spread directly onto hot coal or the fuel bed as per approved operating guidance. Where applicable, dampers may be closed for around 10 minutes to reduce air supply and support treatment action.
The addition frequency depends on fuel type, boiler operating conditions, and severity of soot or fire scale deposition. Frequency may vary from daily use for severe deposition to weekly use as a maintenance dosage.
Note: The frequency of RUB FLOCK 500 soot and fire scale remover addition will depend on the nature of fuel and severity of the problem. Frequency may vary from daily application for severe deposition to weekly application for maintenance dosage. A Rubmech technical representative can advise on the most suitable treatment programme based on fuel type, system condition, and deposit severity.
Safety and Handling
Storage Guidelines
Packing and Availability
Frequently Asked Questions
What are fuel treatment chemicals used for?
What is RUB FLOCK 500?
What is a soot and fire scale remover?
Where can RUB FLOCK 500 be used?
How is RUB FLOCK 500 applied?
How should RUB FLOCK 500 dosage be decided?
Can RUB FLOCK 500 improve combustion efficiency?
Is RUB FLOCK 500 suitable for maintenance dosage?
Related Water Treatment Chemicals

Boiler Water Treatment Chemicals
Prevents scale and corrosion for efficient boiler operation.

Cooling Water Treatment Chemicals
Controls scale, corrosion and fouling in cooling water systems.

RO Plant Treatment Chemicals
Protects membranes and improves reverse osmosis system performance.

Poly Aluminium Chloride (PAC) – RIW Grade
High-performance coagulant for water purification and clarification applications.
Need Fuel Treatment Chemicals for Soot and Fire Scale Control?
Share your boiler, furnace, fuel, soot, clinker, fire scale, or combustion-related requirement to discuss RUB FLOCK 500 product details.